Air-cooled heat exchangers

Air flow is nature’s own method of regulating temperature. Alfa Laval offers a wide range of energy-efficient high-performance systems for air-cooled heat exchange in industrial applications.

Air-cooled heat exchanger range

Explore our different variants of water and air to air heat exchangers.

ACE 640x360px.jpg

Vertical air-cooled finned tube heat exchangers

  • No water required
  • Compact installation
  • Reliable, robust design
  • Typically used in gas compression applications, power generation, and immersion cooling

Air-cooled finned tube heat exchangers

olmi air cooler

Horizontal air-cooled finned tube heat exchangers

  • No water required
  • Suitable for demanding duties
  • Reliable, robust design
  • Typically used in renewable fuel, data center cooling, pipeline compression, refrigeration units, synthetic oil cooling, and downstream oil and gas applications

Air-cooled finned tube heat exchangers

Hybrid air cooler

Hybrid air-cooled heat exchangers

  • Evaporative cooling
  • Minimal water consumption thanks to dynamic cooling
  • Outstanding capacity and low OPEX
  • Typically used in industries such as biofuels, carbon capture, industrial water and waste treatment, oil & gas, refinery, generator cooling, turbine cooling, renewable power, pulp & paper, petrochemicals and steel.

Hybrid air-coolers

Wet surface air cooler

Wet surface air-cooled heat exchangers

  • Evaporative cooling
  • Highly compact alternative to cooling towers
  • Outstanding capacity and low OPEX
  • Typically used in industries such as biofuels, carbon capture, industrial water and waste treatment, oil & gas, refinery, generator cooling, turbine cooling, renewable power, pulp & paper, petrochemicals and steel.

Evaporative air-coolers

Cooling pod for edge data center cooling

Cooling Pod - data center cooling system

  • No water required
  • Complete cooling solution for edge data centers and other modular cooling needs
  • Plug-and-play installation
  • Typically used for edge data center cooling, modular hydrogen generation

Data center cooling system

Air-cooled heat exchangers selection guide

 

  Working pressures Approach temperatures Cooling capacity per installed area Water consumption Energy consumption Maintenance requirements
Vertical air-cooled finned tube heat exchangers <350 bar >5.5°C or >10°F Medium None Medium Low
Horizontal air-cooled finned tube heat exchangers <600 bar >5.5°C or >10°F Low None Medium Low
Hybrid air-cooled heat exchangers <350 bar <5.5°C or <10°F High Minimal Low Medium
Wet surface air-cooled heat exchangers <350 bar <5.5°C or <10°F High Medium Low Medium

 

Nasze dostosowane do potrzeb rozwiązania w zakresie przemysłowych chłodnic powietrza

Znalezienie odpowiedniego rozwiązania w zakresie chłodniczych wymienników ciepła chłodzonych powietrzem do procesów przemysłowych może być dość trudne ze względu na wiele różnych czynników. Jednym z nich jest dostęp do wody - dostęp do wody może być ograniczony lub całkowicie niemożliwy. Możesz również borykać się z problemami związanymi ze zmianami pór roku i innymi wyzwaniami.


W tym filmie dowiesz się więcej o naszej ofercie chłodnic powietrznych i dowiesz się, które rozwiązanie chłodzenia przemysłowego jest idealne dla ciebie w oparciu o twoje konkretne wymagania dotyczące skraplacza chłodnicy powietrznej.